Mr. ugpcba01
Leave a messageMr. ugpcba01
Leave a messageHigh-Speed Differential Signaling: D-PHY uses 1 clock pair + 1~4 data pairs; C-PHY innovatively employs a tri-wire system embedding the clock within data signals.
Ultra-High-Frequency Demands: D-PHY speeds reach 2.5Gbps, while C-PHY achieves up to 5.7Gbps. Such rates demand near-perfect impedance control, signal integrity (SI), and timing synchronization — minor design deviations can cause signal degradation or system failure.
Component Proximity: Keep the distance between the main controller (e.g., AP, SoC) and MIPI interfaces (camera/display connectors) under 50mm to minimize transmission loss and delay.
Optimized Interface Placement: Position MIPI connectors near board edges, considering FPC/FFC cable bend paths to avoid impedance discontinuity caused by stress concentration.
Distance from Noise Sources: Maintain ≥3× signal width (3W rule) between MIPI lines and noise sources (switching power supplies, RF antennas, crystals, DDR buses, motor drivers). Use simulation for complex layouts.
Clean Power Delivery: Place decoupling capacitors (typically 0.1µF + 1µF/10µF) directly adjacent to connector power pins. Prioritize bottom-layer grounding for shortest return paths and noise filtering.
Calculate stackup precisely (use tools like Polar SI9000).
Control trace width (W), dielectric thickness (H), copper weight (T), and permittivity (Er).
Microstrip Differential Impedance (Simplified):Zdiff ≈ (87 / sqrt(Er + 1.41)) * ln(5.98H / (0.8W + T))
Prefer stripline structures for stable impedance and isolation.
High-speed signals are delay-sensitive. Strict length matching ensures synchronous sampling:
Parameter | D-PHY Requirement | C-PHY Requirement | Design Practice |
---|---|---|---|
Intra-Pair Skew | ≤ 5 mil | ≤ 6 mil (per Trio) | Use router tuning features |
Inter-Group Skew | ≤ 100 mil | ≤ 100 mil | Route same-group data together |
Clock-Data Skew | ≤ 12 mil | No separate clock | Match CLK/Data pairs in D-PHY |
Minimize Vias: Use ≤ 2 vias per high-speed path. Place ≥1 accompanying ground via per signal via for low-inductance return paths.
Unbroken Reference Planes: Ensure continuous GND planes below MIPI traces (no splits!). Crossing splits causes impedance jumps and SI failure.
3W Rule: Space MIPI pairs ≥3× trace width from non-MIPI signals (especially single-ended).
Guard Vias & Shielding: Add GND via "fences" along traces and use copper shielding on adjacent layers where feasible (without impedance impact).
Before Gerber release or engaging a PCBA supplier, verify:
Impedance: ✅ 100Ω ±10% (via TDR testing).
Intra-Pair Skew: ✅ ≤5 mil (D-PHY) / ≤6 mil (C-PHY).
Via Count: ✅ ≤2 per pair + accompanying ground vias.
Reference Planes: ✅ Continuous GND under entire route (no splits!).
Spacing: ✅ 3W rule applied; ≥3W from noise sources.
Decoupling Caps: ✅ Placed at connector pins (bottom layer preferred).
Component Placement: ✅ ≤50mm controller-interface distance.
Stackup: ✅ High-speed signals on internal layers (stripline).
Designing for 5Gbps+ MIPI signals is challenging. Statistics show >35% of first-time MIPI designs require ≥2 board spins, increasing costs and time-to-market.
Partnering with an expert PCB design service or full-turnkey PCBA supplier mitigates risks:
Simulation-Driven Design: Use SI/PI tools to predict/optimize impedance, crosstalk, timing, and noise before prototyping.
Process Expertise: Leverage knowledge of high-speed materials (Panasonic Megtron, Isola FR408HR) and processes (back drilling, HDI).
Rigorous Quality Control: Ensure compliance via DRC, impedance testing, flying probe, AOI.
? Contact Our PCB Design Experts Today For:
Free MIPI Design Consultation & Project Review
Competitive PCB Fabrication & PCBA Prototyping/Volume Production Quotes
SI Simulation-Based Design Optimization
Don’t let signal integrity limit innovation. Submit your design inquiry or RFQ for first-time-right success!